An underfloor heating manifold serves as the heart of a wet underfloor heating system. Managing the distribution of heated water from the heat source to different zones. The manifold can provide precise control over multiple zones by regulating the flow through separate pipes. A manifold permits uniform and optimal heating conditions across the entire home.
The manifold plays a crucial role in distributing heated water to the relevant zones. The diagram below displays the relationship between various components in your underfloor heating system. Heated water passes into the system from the heat source, through the blending valve and pump. The heated water flows to the relevant zones which require heat.
Pump/Control Pack
The pump circulates heated water around the system. Using an efficient pump maintains the correct flow rate of water through the system. Our manifold control pack includes a pump, blending valve, and the correct fixtures to connect straight to the manifold.
Below are the dimensions of our underfloor heating manifold and control pack. The installer should allow for the following recommended clearances when mounting the manifold on the wall: 200 mm between the finished floor level and the bottom of the manifold. 100 mm above the manifold. 50 mm on either side of the manifold.
Layout 1 is the standard setup for a manifold. Ball valves are placed between the manifold and the pump. This allows servicing or maintenance without draining the entire system.
Port | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
---|---|---|---|---|---|---|---|---|---|---|---|
A | 189 | 239 | 289 | 339 | 389 | 439 | 489 | 539 | 589 | 639 | 689 |
B | 273 | 323 | 373 | 423 | 473 | 523 | 573 | 623 | 673 | 723 | 773 |
C | 465 | 515 | 565 | 615 | 665 | 715 | 765 | 815 | 865 | 915 | 965 |
A – Width of manifold including fill & drain ports
B – Width of manifold & ball valves
C – Width of manifold, ball valves & pump
Layout 2 is preferred when horizontal space is limited. Installing the ball valves below the pump allows the length to be decreased. Shut-off valves are still included in the system.
Port | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
---|---|---|---|---|---|---|---|---|---|---|---|
A | 189 | 239 | 289 | 339 | 389 | 439 | 489 | 539 | 589 | 639 | 689 |
B | 365 | 415 | 465 | 515 | 565 | 615 | 665 | 715 | 765 | 815 | 865 |
A – Width of manifold including fill & drain ports
B – Width of manifold & ball valves
Below is a quick guide for identifying problems with your underfloor heating manifolds.
An underfloor heating actuator (thermal actuator) provides automatic control of the flow of water through each loop. The actuator is connected to the return port and opens or closes the valve according to signals sent by your wet underfloor heating thermostat. Actuators are normally wired to an underfloor heating wiring centre, which acts as the central hub for the electrical signals.
Underfloor heating actuators can last over 10 years, depending on use. Manufacturer warranties typically cover them for 2 years (Heatmiser) or 5 years (Salus).
Actuators do both – this is their primary function. When the system requires heat, the actuator opens the valve. When the system is off, the actuator closes, stopping the flow of water through the loop. Since actuators are fitted per loop, each loop on the manifold is controlled independently.
Below are the steps to connect your actuator to a VPS manifold. Exact connections may vary depending on the model: